About Us

Moseb Engineering Sdn Bhd is a Flow Expert, Process Control & Electrical company that specialize in providing engineering solutions & services for clients in oil & gas, petrochemical, biomass, pharmaceutical, food & beverage, building & construction, photovoltaic, water and wastewater treatment industries in Malaysia.

Our Mission

To Inspire Industrial Commitment the Professional Ways to Monitor and Verify the Performance Quality of Flow & Process Measuring Instruments Effectively & Accurately, through Optimization System Solutions and Innovative Testing Facilities, in order to enhance Sustainable Energy Development in the Country.

Axioma Factory

QALCOSONIC W1

_
QALCOSONIC W1 - SMART ULTRASONIC WATER METERSPECIFICATIONS

Ultrasonic water meter QALCOSONIC W1 is designed for accurate measurement of cold and hot water consumption in households, apartment buildings and small commercial premises.

It is the first ultrasonic water meter with the integrated Narrow-Band-IoT (NB-IoT) technology in Europe.

FEATURES
• Static method of water consumption measurement, no moving parts, no Air measurement
• High accuracy & Wide measurement range Q3/Q1=R250/400/800(optional), Low flow down to 1LPH
• Eliminates measuring deviations caused by sand, suspended particles or air pockets
• Long-term measurement stability and reliability. No Straight-run required & Installation in any position
• 9 digits, multi-line LCD. Total volume and instantaneous flow rate indication with Archive registration
• Nominal flow 1.6 / 2.5 / 4.0 m3/h; Large Size Nominal flow 6.3/10 m3/h.
• Nominal pressure PN16
• Temperature Class T30, T50, T30/90, T90
• Maintenance free device, battery lifetime > 16 years
• NB-IoT and AMR, NFC, LoRa technology ready
• OIML R49 Compliant / EN ISO 4064 / MID (2014/32/ES) / NMI (Australia)

QALCOSONIC F1(IP65)

_
QALCOSONIC F1 (IP65) - ULTRASONIC WATER METERSPECIFICATIONS

Ultrasonic water meter QALCOSONIC F1 (IP65) is designed for measurement of cold and hot water consumption in households and blocks of flats, as well for industrial applications.
• Static water meter using ultrasonic technology
• High accuracy & Low flow application
• For residential and commercial use: Rain Water/Kitchen/Laundry/Canteen
• Hot and cold water

FEATURES
• Suitable for 15…150mm. Nominal flow 1.6 / 2.5 / 4.0 /6.3 /10 /16 /25 /40 / 63 /100 m3/h
• Dynamic range up to Q3/Q1 = R 250/400
• No straight sections required up to DN50 & No measurement of Air
• Environment protection class B / EN 14154. Protection Class: IP65(Indicator), IP67(Sensor)
• Pressure PN16/25 Bar
• Temperature measurement Pt500, 0° C … 180° C (T30, T30/90, T90)
• Internal Logging – Metering data archive (Hourly/ Daily/ Monthly)
• Power supply options: 24Vdc/ 230Vac/ Battery (10 – 12 Years)
• Ultrasonic water meter QALCOSONIC F1/ FLOW 4 has optional communication modules
• Ultrasonic water meter can be mounted in any installation position
• WMBUS modes: Axis (bidirectional), S1 and T1 OMS modes
• “Walk By”, “Drive By”, Optical Interface for Data Archive Download & Configuration
• Communication modules: M-BUS, CL, WMBus 868 MHz, MODBus RS485, MiniBus, LORA, Bacnet
**NOTE: For 150MM, the model will be Qalcosonic E2 Flow.

QALCOSONIC F1(IP68)

_
QALCOSONIC F1 (IP68) - ULTRASONIC WATER METERSPECIFICATIONS

Ultrasonic water meter QALCOSONIC F1 (IP68) is designed for measurement of cold and hot water consumption in households and blocks of flats, as well for industrial applications.
• Static water meter using ultrasonic technology
• High accuracy & Low flow application
• For residential and commercial use: Rain Water/Kitchen/Laundry/Canteen
• Hot and cold water

FEATURES
• Suitable for 15…100mm. Nominal flow 1.6 / 2.5 / 4.0 /6.3 /10 /16 /25 /40 / 63 /100 m3/h
• Dynamic range up to Q3/Q1 = R 250/400
• No straight sections required up to DN50 & No measurement of Air
• Environment protection class B/C. Protection Class: IP68
• Pressure PN16/25 Bar
• Temperature measurement Pt500, 0° C … 180° C (T30, T30/90, T90)
• Internal Logging – Metering data archive (Hourly/ Daily/ Monthly)
• Power supply options: 24Vdc/ 230Vac/ Battery (>16 Years)
• Ultrasonic water meter QALCOSONIC F1/ FLOW 4 has optional communication modules
• Ultrasonic water meter can be mounted in any installation position
• WMBUS modes: Axis (bidirectional), S1 and T1 OMS modes
• “Walk By”, “Drive By”, Optical Interface for Data Archive Download & Configuration
• Communication modules: M-BUS, CL, WMBus 868 MHz, MODBus RS485, MiniBus, LORA, Bacnet

QALCOSONIC E1

_
QALCOSONIC E1 - HEAT AND COOLING ENERGY WATER METERSPECIFICATIONS

Heating and Cooling Energy Water Meter QALCOSONIC E1 is designed for commercial metering of the heating and cooling energy when the heat transfer medium is water; it is used in the District Cooling / Heating facilities (in residential or commercial buildings, hospital and factories facilities, etc.).

FEATURES
• Suitable for 15…150mm. Nominal flow 0.6 / 1.0/ 1.5 / 2.5/ 3.5 / 6.0/ 10/ 15/ 25/ 40/ 60/ 150 m3/h
• Dynamic range up to Q3/Q1 = R 100/250
• No straight sections required up to DN50 & No measurement of Air
• Environment protection class B / EN 14154. Protection Class: IP65(Indicator), IP67(Sensor)
• Pressure PN16/25 Bar
• Temperature measurement Pt500, 0° C … 130° C, 1.2 – 5m Cable Length
• Internal Logging – Metering data archive (Hourly/ Daily/ Monthly)
• Power supply options: 24Vdc/ 230Vac/ Battery (10 – 12 Years)
• Tariff Functions & Pulse Output(Energy/Volume)
• Ultrasonic water meter QALCOSONIC E1/ Heat 1 has optional communication modules
• Ultrasonic water meter can be mounted in any installation position
• WMBUS modes: Axis (bidirectional), S1 and T1 OMS modes
• “Walk By”, “Drive By”, Optical Interface for Data Archive Download & Configuration
• Communication modules: M-BUS, CL, WMBus 868 MHz, MODBus RS485, MiniBus, LORA, Bacnet
**NOTE: For 150MM, the model will be Qalcosonic E2 Flow.

QALCOSONIC E2

_
QALCOSONIC E2 – ADVANCE HEAT AND COOLING METERSPECIFICATIONS

Ultrasonic Heating & Cooling Energy Water Meter Qalcosonic E2 is designed for thermal energy and water quantity measurements in closed-type heating and cooling systems as well as for thermal energy and water quantity measurements in open-type heating systems and measurements of various liquid quantities.

FEATURES
• Suitable for 15…400mm. Nominal flow 0.6 / 1.0/ 1.5 / 2.5/ 3.5 / 6.0/ 10/ 15/ 25/ 40/ 60/ 100/ 150/ 250/ 400/ 560/ 750/ 950 m3/h
• Dynamic range up to Q3/Q1 = R 100/250
• Dual Energy Measurement Systems for either Heating or/and Cooling application
• Two mA input pressure measurement channels, Two pulse inputs for additional flow sensors
• No straight sections required up to DN50 & No measurement of Air
• Environment protection class B / EN 14154. Protection Class: IP65(Indicator), IP67(Sensor)
• Pressure PN16/25 Bar
• Temperature measurement Pt500, 0° C … 130° C, 1.2 – 5m Cable Length
• Internal Logging – Metering data archive (Hourly/ Daily/ Monthly)
• Power supply options: 230Vac/ Battery (10 – 12 Years)
• Tariff Functions
• Ultrasonic water meter QALCOSONIC E1/ Heat 1 has optional communication modules
• Ultrasonic water meter can be mounted in any installation position
• WMBUS modes: Axis (bidirectional), S1 and T1 OMS modes
• “Walk By”, “Drive By”, Optical Interface for Data Archive Download & Configuration
• Output: Dual Pulse, Dual 0-20mA/4-20mA Current Output (optional) and NO/NC Relays output
• Selective Communication modules: M-BUS, CL, WMBus 868 MHz, MODBus RS485, MiniBus, LORA, Bacnet

QALCOSONIC E3

_
QALCOSONIC E3 – NEW GENERATION HEAT AND COOLING METERSPECIFICATIONS

QALCOSONIC E3 Heat & Cooling Ultrasonic Water Meter is designed to measure the heat and cooling energy consumption, where data are recorded in two separate registers. The meter is used in the district heating objects (residential houses, companies and organisations, heat supply facilities, etc.).

ADVANTAGE
• Flexible meter configurations. (Metering parameters can be set by users) o Choose required measurement units;
o Set the place of installation (return or supply);
o Configure the impulse inputs and outputs;
o Control computing modules. FEATURES

  • Suitable for 15…100mm. Nominal flow 0.6 / 1.0/ 1.5 / 2.5/ 3.5 / 6.0/ 10/ 15/ 25/ 40/ 60 m3/h
  • Dynamic range up to Q3/Q1 = R 100/250
  • No straight sections required up to DN50 & No measurement of Air
  • Environment protection class B / EN 14154. Protection Class: IP65(Indicator), IP67(Sensor)
  • Pressure PN16/25 Bar
  • Temperature measurement Pt500, 0° C … 130° C, 1.2 – 5m Cable Length
  • Internal Logging – Metering data archive (Hourly/ Daily/ Monthly)
  • Power supply options: 24Vdc/ 230Vac/ Battery (10 – 12 Years)
  • Tariff Functions & Pulse Output(Energy/Volume)
  • Ultrasonic water meter can be mounted in any installation position
  • WMBUS modes: Axis (bidirectional), S1 and T1 OMS modes
  • “Walk By”, “Drive By”, Optical Interface for Data Archive Download & Configuration
  • Communication modules: M-BUS, CL, WMBus 868 MHz, MODBus RS485, MiniBus, LORA, Bacnet

QALCOSONIC E4

_
QALCOSONIC E4 – NEW GENERATION HEAT AND COOLING METERSPECIFICATIONS

QALCOSONIC E4 Heat & Cooling Ultrasonic Water Meter is designed to measure the heat and cooling energy consumption, where data are recorded in two separate registers. The meter is used in the district heating objects (residential houses, companies and organisations, heat supply facilities, etc.).

ADVANTAGE

  • Composite flow part body
  • Flexible meter configurations. (Metering parameters can be set by users)
    o Choose required measurement units;
    o Set the place of installation (return or supply); o Configure the impulse inputs and outputs;
    o Control computing modules.

FEATURES

  • Suitable for 15…40mm. Nominal flow 0.6 / 1.0/ 1.5 / 2.5/ 3.5 / 6.0/ 10 m3/h
  • Dynamic range up to Q3/Q1 = R 100/250
  • No straight sections required & No measurement of Air
  • Environment protection class B / EN 14154. Protection Class: IP65(Indicator), IP67(Sensor)
  • Pressure PN16/25 Bar
  • Temperature measurement Pt500, 0° C … 130° C, 1.2 – 5m Cable Length
  • Internal Logging – Metering data archive (Hourly/ Daily/ Monthly)
  • Power supply options: 24Vdc/ 230Vac/ Battery (10 – 12 Years)
  • Tariff Functions & Pulse Output(Energy/Volume)
  • Ultrasonic water meter can be mounted in any installation position
  • WMBUS modes: Axis (bidirectional), S1 and T1 OMS modes
  • “Walk By”, “Drive By”, Optical Interface for Data Archive Download & Configuration
  • Communication modules: M-BUS, CL, WMBus 868 MHz, MODBus RS485, MiniBus, LORA, Bacnet

QALCOMET E1

_
QALCOMET E1 – BTU ENERGY CALCULATORSPECIFICATIONS

QALCOMET E1 BTU Energy Calculator is energy calculator designed for metering and monitoring of heating and cooling energy in closed or open heating/cooling systems, installed in dwelling houses, office buildings or energy plants.
The energy calculator QALCOMET E1 is a sub-assembly of a heat meter, together with standard flow sensors (based on ultrasonic, electromagnetic or mechanical measurement principle with standard pulse output), temperature and pressure sensors.
Heat calculator QALCOMET E1 measures and calculates supplied flow parameters, displays measurement data on the display, records and stores data in the internal archive.

ADVANTAGES
• Energy calculator QALCOMET E1 can be used to calculate energy values for two independent heating/cooling systems
• Energy calculator QALCOMET E1 has flexible menu setup – list of parameter values displayed on the LCD may be configured according to the customer’s needs
• User may select one of seven possible installation diagrams according to the application type.
• Up to 5 flow measurement inputs
• Up to 5 temperature sensors
• Two mA input pressure measurement channels, Two pulse inputs for additional flow sensors
• Internal Logging – Metering data archive (Hourly/ Daily/ Monthly)
• Optical data interface according to EN 61107
• Battery lifetime up to12 years
• Fulfils “C” class environment protection requirements
• Energy calculator QALCOMET E1 conforms protection class IP 65
• Programmable built-in alarm relays or regulation functions
• Temperature measurement Pt 500/Pt 1000,0°C…160°C
• WMBUS modes: Axis (bidirectional), S1 and T1 OMS modes
• “Walk By”, “Drive By”, Optical Interface for Data Archive Download & Configuration
• Output: Dual Pulse, Dual 0-20mA/4-20mA Current Output (optional) and NO/NC Relays output
• Selective Communication modules: M-BUS, CL, WMBus 868 MHz, MODBus RS485, MiniBus, LORA, Bacnet

aTERMINAL

_
aTERMINAL WALK-BY RADIO PORTABLE LOGGERSPECIFICATIONS

aTERMINAL is a device designed for the remote reading of meters and their binding with the permanent data reading antenna of data from meters manufactured by Axis Industries with a 868 MHz communication interface.

SPECIAL FEATURES
• Communication interface RF868.
• Can be used as servise tool for AMR radio network configuration.
• Configurable WMBus mode – T1, S1, Axis (bidirectional communication).
• Internal expandable memory: microSD card.
• Have direction,/selection keys and graphic display.
• Device power supply: rechargeable Li-Ion battery, charging via miniUSB / 230 V adapter

App NOTE

Contact Us

_

Moseb Engineering Sdn Bhd (907436-U)

  • AddressNo. 33, Jalan Layang layang 5, Bandar Puchong Jaya, 47100 Puchong, Selangor Darul Ehsan, Malaysia
  • Emailsales@mosebengineering.com
  • Contact603-8080 8110
  • Fax+603-8080 8105
  • Hotline+6016 – 921 5881